Product Introduction
■ Safe:
- Early thermal runaway prewarning and PACK-level combustible gas detection to realize targeted fire extinguishing bycoordinating with BMS and EMS;
Using flame retardant material and multiple ESS can be connected seamlessly,saving 20%of space and reducing maintenancecost by 10%;
- Patented bionic tree runner design with PACKtemperature difference≤5℃and battery cycle life increased by 12%;
- Adopt "emergency avoidance design"with BMS and EMS online backup to reduce failure rate by 5%;
- DYNAMIC and safe designwith core components (air conditioners,PCS)integrated within the cabinet to reduce the risk of hidden failure.
■ Simple:
- All-in-one design and modular installation with single cabinet covering an area of just 1.68m²;
- Applicableto multiple industrial scenarios and easy to connect to the grid;
- Easily plug and play with aviation plug and simple capacity expansion covering power range from 50kW to 1MW;
- Factory prefabrication and integrated transportation to reduce the transportation,installation and commissioning fees by 15%.
■ Smart:
Remote cloud operation and maintenance,supporting remote and local monitoring;
- Smart balancing strategy and system AI prewarning to ensure the consistency of battery life cycle;
- Support black start functionwith reliable power supply in off-grid/micro-grd mode;
- Support a variety of operation modes (virtual power plant,grid-connected,off-grid)to improve revenue.
| Type | Name | Parameters |
| Battery parameters | Cell type | EM215KP |
| System configuration | 1P240S | |
| Rated energy | 215.04KWh | |
| Voltage | 768 | |
| Voltage range | 672~864 | |
| AC parameters (gridconnected) | Rated power | 100kW |
| Maximum power | 110kW | |
| Wiring mode | Three-phase four-wire/three-phase three-wire | |
| Rated grid voltage | 400V | |
| Voltage range | 320~460V | |
| Rated current | 144A | |
| Rated grid frequency | 50/60Hz | |
| THDi | <3%(Ratedpower) | |
| Power factor adjustable range | -1(ahead)~1(lag | |
| AC Parameters (offgrid) | AC off-grid voltage | 400 |
| AC off-grid frequency | 50/60 | |
| AC voltage range | ±3% | |
| Off-grid output voltage distortionrate | <3%(Linear load) | |
| System parameters | System Efficiency | ≥90% |
| Charge-discharge rate | ≤0.5CP | |
| Thermal management mode | Air-cooling | |
| Fire protection system | Type Saerosol / HFC-propane /perfluorohexanone | |
| Anticorrosivelevel | C3(C4/C5optional) | |
| Ingressprotection | IP54 | |
| DimensionD*W*H | 1400*1200*2200mm | |
| Weight | 2300kg | |
| Ambient parameters | Operating temperature range | -15~+45℃(>45℃derating) |
| Operating humidity range | 0~95%(nocondensastion) | |
| Altitude | 2000m(>2000m derating) | |
| communication | Communication | Ethernet、RS485 |
| External system communication protocol | ModbusTCP、IEC61850、ModbusRTU | |
| Certificate | Certificate | GB/T36276、 GB/T34131、 UL1973 UL9540A、 IEC62619、 UN38.3 |